Executive summary
A robot detects every hole in a test series. Whether its readings are accurate enough for a tolerance decision remains an open question. Giriraj Mannayee investigates an optical measurement system in which a neural network identifies the visible region of a blind hole. All 30 trials detected the hole, yet the position and diameter errors differed. These trials measure the performance of the complete system. The contribution of segmentation by artificial intelligence (AI) relative to conventional edge detection was not measured separately.
FQI takeaway
- Report detection rate alongside measurement errors in millimetres.
- Check position and diameter on the same workpiece using a reference method.
- Deliberately sample rare combinations of depth, reflectivity and approach angle.
The principle at a glance
A blind hole can be accessed from only one end. Depending on the camera angle, its circular rim appears elliptical. A reflection can create an apparent edge. The apparatus adjusts the illumination, and the network generates a map of the pixels likely to belong to the measurement region. The system fits a shape to the selected boundary points and uses the calibrated camera position to obtain dimensions. A consistently identified edge can still be displaced from the physical boundary.
Deep dive
The reference instrument is a coordinate measuring machine. Mean spatial position error was about 0.032 millimetres, while mean absolute diameter error was about 0.054 millimetres. Consider a simplified example in which the estimated edge lies slightly outside the true rim all the way around. Its centre can remain accurate while its diameter increases. The confidence assigned by the segmentation network has no unit of length and cannot directly be compared with a dimensional tolerance.
FQI proposes a table with one row per hole and exposure. Record the reference and measured values, view angle, surface condition and lighting. Repeat the approach to see how much the measurements vary between attempts. Comparison with the independent reference can also reveal a persistent offset. The test plan should specify when to retake an image and when to use an independent measurement to decide a borderline case.
Inspect the raw images for unusually large diameter errors. An operator could hold the image mask fixed, rerun the analysis and then change only the camera position estimate. A result sensitive to the latter calls for a different investigation from a boundary that moves within an unchanged image. This is a proposed diagnostic, not a decomposition of uncertainty established by the paper. Include rejected images and unsuccessful attempts in the report so that dimensional accuracy is not reported solely for the easiest parts to measure.
Limitations and risks
The trials cover diameters from five to fifteen millimetres. Only five cases combine a high depth-to-diameter ratio with a steep approach angle under the study’s definitions. A mean across all trials can conceal these combinations. Laboratory results also leave open the effect of a different material, gripper or tighter tolerance.
FQI conclusion
Start an operational assessment with reference parts close to the tolerance limits that affect a real decision. The metrology team can then specify the geometries for which it accepts a position or diameter reading and the conditions that trigger a second measurement. This gives production staff a rule for a particular station. A single confidence value from the network cannot supply that rule.
Sources & transparency
The readings come from Mannayee’s experimental series. The linked industry report led to the peer-reviewed original study. Operational examples and proposed checks are FQI interpretations. Sources reviewed on 4 November 2026. Artificial intelligence assisted preparation. Johann Fischer explicitly approved this article package for publication on 2026-11-04.